TM 9-2350-287-20-1
6-7. AERATION DETECTOR REPLACEMENT (continued).
e.
INSTALLATION
WARNING
Adhesives can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. If adhesive gets on skin or clothing, wash immediately with soap and
water.
1,
If hoses (5 and 11) were removed, apply adhesive to tube at interfaces, install two hoses (5 and 11) on vehicle,
and tighten two clamps (6 and 12).
2.
Install bracket (14) and two screws (9), new Iockwashers (8), and washers (7) on vehicle.
3.
Install aeration detector (20) and four screws (13), new Iockwashers (2), washers (3), and nuts(1) on bracket
(14).
4.
Apply adhesive to tube at interface, install two hoses (5 and 11) on aeration detector (20), and tighten two
clamps (4 and 10).
5.
Install washer (15), ground lead (16), new Iockwasher (1 7), and screw(18) on transmission.
6.
6-19
FOLLOW-ON MAINTENANCE:
Refill cooling system (refer to TM 9-2350-287-10)
Close air intake grille (refer to TM 9-2350-287-10).
Install pressure relief valve block mount (para 6-2).
Close right transmission access door (refer to TM 9-2350-10).
Connect two electrical leads, 352A and 352B (19), to aeration detector (20).