6-4. SURGE TANK HOSES REPLACEMENT (continued).
5.
6.
7.
8.
9.
10.
11.
12.
13.
b.
Remove two screws (29), Iockwashers (31 ), and nuts (32) and hose (33) from two clamps (30) at transmission.
Discard Iockwashers.
Loosen two clamps (34 and 35) and remove hose (33) from elbow (28) and tube (36).
Remove two screws (41), Iockwashers (42), and clamps (43 and 44) from tube (36). Discard Iockwashers.
Loosen clamp (37) and remove tube (36) from hose (38).
Loosen clamp (39) and remove hose (38) from lower radiator crossover pipe (40),
Loosen nut (23) at crossover tube (24) and nut (26) at elbow (27).
Remove screw (21 ), Iockwasher (20), washer (1 9), and clamp(18) from radiator fan. Discard Iockwasher.
Remove hose (25) from elbow (27) and crossover tube (24).
Remove two clamps (16 and 22) and hose (17) from elbow (15) and radiator.
INSTALLATION
1.
2.
3.
4.
5.
6.
7.
8.
WARNING
Adhesives can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open flame and use in a well-
ventilated area. If adhesive gets on skin or clothing, wash immediately with soap and
water.
Apply adhesive to both ends of hose (17), and install hose(17) and two clamps (16 and 22) on elbow (15) and
radiator.
Install hose (25) on elbow (27) and crossover tube (24), tighten nut (26) at elbow (27), and tighten nut (23)
at crossover tube (24).
Install clamp (18), screw (21 ), new Iockwasher (20), and washer(19) on radiator fan.
Apply adhesive to both ends of hose (38), install hose (38) on lower radiator crossover pipe (40), and tighten
clamp (39).
install tube (36) on hose (38), and tighten clamp (37).
Install two clamps (43 and 44), screws (41 ), and new Iockwashers (42) on tube (36).
Apply adhesive to both ends of hose (33), and install hose (33) on elbow (28) and tube (36), and tighten two
clamps (34 and 35).
Install two clamps (30), screws (29), new Iockwashers (31), and nuts (32) on hose (33) at transmission.
6-8