6-3. SURGE TANK REPLACEMENT (continued).
NOTE
Remove only those pads that are defective and need to be replaced.
9.
Scrape pads (22) from hull.
10.
Drycleaning solvent P-D-680 is toxic and flammabil. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT use near open flame or excessive heat.
Clean pad mounting surface throughly with drycleaning solvent rag.
b.
INSTALLATION
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in a well-ventilated area. if adhesive or sealing compound gets on skin or
clothing, wash immediately with soap and water.
1.
Apply adhesive to new pads (22) only, and install pads (22) on hull.
2.
Install surge tank (21 ) in vehicle.
6-5
TM 9-2350-287-20-1
WARNING