TM 9-2350-287-20-14-24.HEAT SHIELD REPAIR (continued).11.Remove heat shield thermal insulation (48) from heat shield (1) with putty knife. Discard thermal insulation.c.CLEANING AND INSPECTIONWARNINGDry-cleaning solvent P-D-680 is toxic and flammable. Always wear protectivegoggles and gloves, and use only in a well-ventilated area. Avoid contact with skin,eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame orexcessive heat.1.Clean all metal parts with dry-cleaning solvent.2.Clean thermal insulation mounting surface with dry-cleaning solvent to remove all residue and old thermalinsulation adhesive.3.Inspect all parts for damage. Replace any damaged parts.d.ASSEMBLY1.Apply rubber adhesive to new thermal insulation (48), and install thermal insulation (48) on heat shield (1).2.Install seal (36) and shield retain plate (47) on heat shield (1) with five washers (46) and new self-locking nuts(45).Change 1 4-68[Text and Art Deleted]
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business