TM 8-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).w. AFES, CREW (continued).(5) CREW BOTTLES NOT FULLY DISCHARGING/NOT EXTINGUISHING FIRES.Initial Setup:Tools/Test Equipment:Equipment Conditions:l Automotive wrench (Item 4, Appendix 1). Left projectile rack assembly moved to rearl General mechanic’s tool kit (Item 24,of vehicle (refer to TM 9-2350-287-10).Appendix I). Crew AFES Test/Alarm panel MAINT switch inmaintenance position (para 21-3).NOTEl Instead of using multi meterfor voltage check, STE/lCEtroubleshooting,INDIVIDUALBATTERY VOLTAGE TEST- TEST89 maybe performed.l Instead of using multi meterfor continuity check, STE/lCEtroubleshooting, TEST 91 maybe performed.A. Check pressure gage of crew fire extinguisher.The black needle of the pressure gage shouldbe inside the green wedge.Is pressure gage in the correct position?IReplace crew fire extinguisher cylinderbottle (para 21-5).Verify problem issolved.IB. Check dispersal nozzles for proper installa-tion. Red notch on dispersal nozzle shouldline up with red notch on bottle assembly.Are nozzles lined up?IInstall dispersal nozzle in bottle assembly.Back up nozzle not more than 1 full turn toline up red notches. Verify problem issolved.Recheck steps A and B to ensurecorrectness. Verify problem is solved.END OF TASKCREW FIRE EXTINGUISHERCYLINDER BOTTLEPRESSUREGAGEIDISPERSALNOZZLE2-358