TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).o. PERSONNEL VENTILATION BLOWER (continued).(I) PERSONNEL VENTILATION BLOWER DOESNOT OPERATE. All other electrical componentsoperate (continued).CONTINUED FROM AA.a. AFES relay #2, terminal 2 and chassis.b. AFES relay #1, terminal 2 and chassis.c. Harness 12351461, pin D, at connectionto AFES harness 12352354.d. Harness 12351461, pin D, at connectionto AFES harness 12352316.Do all ground points check out good?Repair or replace harness 12351461 (para7-79). Verify problem is solved.1B. 1. Disconnect wire harness 12351461 fromventilation blower motor.2. Place red lead of multimeter in socket A ofplug and ground black lead.3. Turn MASTER switch ON (refer to TM 9-2350-287-10).4. Press PERSONNELBLOWER toggle switch totion.5. Check for 24 +3 vdc.VENTILATOREXHAUST posi-6. Turn MASTER switch OFF (refer to TM 9-2350-287-10).Is voltage present in the exhaust circuits?Replace personnel ventilator blower (para7-81). Verify problem solved.Continued on next page2-250