TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).n.PERSONNEL HEATER (continued).(3) PERSONNEL HEATER CONTINUES RUNNINGWITH HEAT SELECTOR SWITCH TURNED OFF.All other electrical systems operate.A.1. Disconnect harness 12351544 from per-sonnel heater.2. Place red lead of multimeter in socket Cand ground black lead.3. Have assistant turn MASTER switch ON(refer to TM 9-2350-287-10).4. Check for 24 +3 vdc.5. Turn MASTER switch OFF (refer to TM 9-2350-287-1 0).Is voltage indicated?Replace accessory control box (para 7-10). Verify problem is solved.Repair or replace personnel heater(para 16-7). Verify problem is solved.END OF TASK2-247