TM 9-2350-287-20-1
2-19. TROUBLESHOOTING CHART (continued).
e. AIR CLEANER FAN ASSEMBLY (continued).
(1) AIR CLEANER BLOWER MOTORS DO NOT
OPERATE WITH VEHICLE IN GEAR (continued).
CONTINUED FROM H
1.
Disconnect wire 12353259 from air cleaner
blower motor relay.
2. Remove jumper wire and place one lead of
multimeter at wire 415B neutral safety switch
connector and place the other multi meter lead
in connector of harness 12353259 air cleaner
blower motor relay connector.
3. Check wire 415B for continuity.
Is continuity indicated?
J. 1. Reconnect wires 415A and 415B to neutral
safety switch.
2. Disconnect wire 415 of harness 12353259
from wire 415 of harness 12351544.
3. Place one lead of multimeter in connector
B of harness 12353259 and place the other
Iead of multimeterin wire 41 5 pin connector of
harness 12353259.
4. Check wire 415 for continuity.
Is continuity indicated?
Repair wire 415 or replace wire harness
12353259 (para 7-63). Verify problem is solved.
Repair or replace air cleaner blower motor relay
(para 7-12). Verify problem is solved.
END OF TASK
2-86
Repair wire 415B or replace wire
Harness 12353259 (para 7-63).
Verify problem is solved.