TM 9-2350-277-34
REPLACE DIODE AND MOTOR RESISTOR Continued
0083 00
4.
Remove nut (8), screw (9), and motor resistor (6) from bracket (10).
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
1.
Use multimeter to check diode. Set meter to above 200 ohms range. Place probes on each end of diode and note reading.
Switch probes and note reading. One reading must indicate continuity and other reading must indicate high resistance, if
they do not replace diode.
2.
Use multimeter to check motor resistor. Multimeter must read 250-300 ohms. Replace out of range resistor.
0083 00-2