TM 9-2350-277-34REPAIR POWER PLANT DOOR HINGE — Continued 0047 00INSTALLATION1. Tack weld hinge (2) or (3) to door (4). Recheck measurement shown before completing required weld.2. Complete weld on new hinge. See TM 9-237. Use electrode 5356.3. Clean the weld area and apply touch-up paint to repaired area. See TM 43-0139.FOLLOW-THROUGH STEPS1. Install door on carrier (see your -20).2. Install seal on hinge edge of door (see your -20).END OF TASK0047 00-3/4 blank