TM 9-2350-277-34REPAIR POWER PLANT DOOR HINGE 0047 00THIS WORK PACKAGE COVERS:Removal (page 0047 00-1).Installation (page 0047 00-3).INITIAL SETUP:Maintenance LevelDirect SupportTools and Special ToolsMetal Worker’s Tool Kit (WP 0120 00, Item 63)Trailer Mounted Welding Shop (WP 0120 00, Item 69)Sander Spindle Adapter (WP 0120 00, Item 1)Welder’s Gloves (WP 0120 00, Item 18)Industrial Goggles (WP 0120 00, Item 19)Welder’s Helmet (WP 0120 00, Item 21)Electric Disc Sander (WP 0120 00, Item 46)Arc Welding Machine (WP 0120 00, Item 68)Materials/PartsEnamel (WP 0122 00, Item 12)Welding electrode (WP 0122 00, Item 35)Personnel RequiredMetal Worker 44B10ReferencesSee your -20TM 43-0139TM 9-237Equipment ConditionPower plant door removed (see your -20)Power plant door seal removed from hinge (see your -20)REMOVAL1. Remove remaining portion of damaged hinge (1) or (2) from door (3).WARNINGMetal chips and grinding dust can cause injury. Wear goggles and gloves.2. Use a machinist hammer and a cold chisel to chip off remaining part of bad hinge (1) or (2) from door (3).0047 00-1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business