TM 9-2350-277-20-5REPLACE RAMP CONTROL VALVE (WITH INTERNAL RELIEF VALVE) AND FITTINGS —Continued0661 008. Connect elbow (5) with hose (6) to elbow (7).9. Connect quick disconnect (8) on hose (9) to quick disconnect (10) on valve (2).10. Connect tube (11) to elbow (12) on valve (2).FOLLOW-THROUGH STEPS1. Fill hydraulic reservoir (WP 0155 00).2. Install drivers access panel (see your -10).3. Raise and lower ramp several times to bleed system and check for leaks (see your -10).4. Raise and lock ramp (see your -10).END OF TASK0661 00-7/8 blank