TM 9-2350-277-20-5
REPLACE RAMP CONTROL VALVE (WITH INTERNAL RELIEF VALVE) AND FITTINGS
Continued
0661 00
5.
Remove four screws (1) and tab washers (2) from valve (3). Remove valve from bulkhead. Discard tab washers.
6.
Remove two elbows (4)(5) and preformed packings (6) from valve (3). Discard packings.
7.
Remove quick disconnect (7) and adapter (8) from coupling (9).
8.
Remove coupling (9), adapter (10), and preformed packing (11) from valve (3). Discard packing.
0661 00-3