TM 9-2350-277-20-3
REPLACE MASTER SWITCH (M113A3, M901A3, M1059A3, M1064A3, AND M58 ONLY)
Continued
0262 00
3.
Install conductor bus (9) with attached leads on terminal (10) . Secure with new lockwasher (11) and nut (12) .
4.
Install circuit 49 lead (13) and circuit 50 lead (14) on terminal (15) . Secure with new lockwasher (16) and nut (17) .
5.
Install master switch panel (8) on distribution box (18) . Secure with eight screws (19) , washers (20) , and new
locknuts (21) .
6.
Connect circuit 37 lead (22) to connector (23) .
FOLLOW-THROUGH STEPS
1.
Install warning light panel assembly(WP 0291 00).
2.
Connect infrared power supply cable to dummy connector (see your 10).
3.
Connect battery ground strap (WP 0337 00).
4.
Turn MASTER SWITCH ON (see your 10).
5.
Check that MASTER SWITCH ON indicator light comes ON (see your 10).
6.
Turn MASTER SWITCH OFF (see your 10).
END OF TASK