TM 9-2350-277-20-1
NO AC POWER FROM INVERTERS (M1068A3 ONLY)Continued
0109 00
2Y
1. Set MASTER SWITCH to OFF.
2. Tag leads E1 thru E5 before removal. Remove cable W5 leads (1)
from posts on terminal block TB2 (2).
3. Measure resistance between sockets of plug P6 (3) and W5 leads
(1) as follows:
Socket A to lead E1
Socket B to lead E2
Socket C to lead E3
Socket D to lead E4
Socket E to lead E5
4. Does multimeter read 0 ohms for each measurement?
YES
NO
2YN
1. Replace cable W5 (WP 0839 00).
2. Verify no faults found.
0109 00-4