TM 9-2350-277-20-1
NO DC OUTPUT FROM DC POWER SUPPLY (M1068A3 ONLY)Continued
0108 00
3Y
1. Measure resistance between circuit 10B terminals (1) on Power
Supply PS2 (2) and Power Supply PS1 (3).
2. Measure resistance between circuit 8C terminals (4) on Power
Supply PS2 (2) and Power Supply PS1 (3).
3. Measure resistance between circuit 3Z terminals (5) on Power
Supply PS2 (2) and Power Supply PS1 (3).
4. Does multimeter read 0 ohms for each measurement?
YES
NO
3YN
1. Faulty lead 10B, 8C, and 3Z in
Power Control Enclosure. Beyond
unit maintenance repair.
2. Notify supervisor.
4Y
1. Faulty Power Supply. Beyond unit maintenance repair.
2. Notify supervisor.
0108 00-5/6 blank