TM 9-2350-277-20-1
NO DATA OUTPUT FROM DATA PANEL A12 (M1068A3 ONLY)Continued
0110 00
Y
1. Remove cable W124 plug P109 (1) from Patch Panel Box A10
jack J140 (2).
2. Measure resistance between pin A on plug P109 (1) and socket A
on plug P1 (3) of cable W124. Repeat for pins B through a.
3. Does multimeter read 0 ohms for each measurement?
YES
NO
YN
1. Replace cable W124 (WP 0855 00).
2. Verify no faults found.
2Y
1. Replace Signal Patch Panel Box A10 (WP 0816 00).
2. Verify no faults found.