TM 9-2350-277-20-1NO AC POWER FROM INVERTERS (M1068A3 ONLY)—Continued 0109 00T1. Remove cable W5 plug P6 (1) from Power Control Enclosurejack J27 (2).2. Set MASTER SWITCH to ON.3. If popped out, press DC TO INVERTERS button (3) on PowerControl Enclosure panel.4. Does DC VOLTS meter (4) on Power Control Enclosure panelread 26 volts DC or more?YESNOTN1. Go to: Power Control Enclosure A1DC Input/Output Inoperative(WP 0090 00).0109 00-2