TM 9-2350-277-20-1
NO DC OUTPUT FROM DC POWER SUPPLY (M1068A3 ONLY)Continued
0108 00
Y
1. Set DC POWER SUPPLY circuit breaker on Power Control
Enclosure panel to ON.
2. Measure voltage between CB5 terminal 1 (1) and terminal block
E4 (2). Also measure voltage from CB5 terminal 2 (3) to E4 (2).
3. Does multimeter read 110 volts AC or more for both
measurements?
YES
NO
YN
1. Replace circuit breaker CB5
(WP 0828 00).
2. Verify no faults found.
0108 00-3