TM 9-2350-277-20-1
NO DC POWER FROM TENT INTERFACE PANEL A5 (M1068A3 ONLY)Continued
0092 00
BY
1. Turn MASTER SWITCH to OFF (see your -10).
2. Remove ten screws (1) and lockwashers (2) and lower faceplate
(3). Discard lockwashers.
3. Set DC TENT INTERFACE panel circuit breaker to ON TM
11-7010-256-12&P.
4. Measure resistance between terminals (4) of circuit breaker CB16
(5).
5. Does multimeter read 0 ohms?
YES
NO
BYN
1. Replace circuit breaker CB16
(WP 0827 00).
2. Verify no faults found.
B2Y
1. Raise faceplate and secure to Power Control Enclosure with ten
new lockwashers and screws.
2. Go to: Power Control Enclosure A1 DC Input/Output Inoperative
(M1068A3 Only) (WP 0090 00).
0092 00-4