TM 9-2350-277-20-1NO DC POWER FROM TENT INTERFACE PANEL A5 (M1068A3 ONLY)—Continued 0092 00T1. Remove cable W32, plug P16 (1) from Power Control Enclosurejack J36 (2).2. Turn MASTER SWITCH to ON (see your -10).3. Set DC TENT INTERFACE panel switch to ON TM11-7010-256-12&P.4. Measure voltage between jack J36 (2) socket A to socket B.5. Does multimeter read 22 volts DC or more?YESNOGO TO BY (PAGE 0092 00-4)0092 00-2