TM 9-2350-277-20-1NO AC POWER FROM TENT INTERFACE PANEL A5 (M1068A3 ONLY)—Continued 0091 00BY1. Remove ALL power from SICPS system, (see your -10) and TM11-7010-256-12&P.2. Remove ten screws (1) and lockwashers (2), and lower faceplate(3). Discard lockwashers.3. Apply AC power to the SICPS system, (see your -10) and TM11-7010-256-12&P.4. Set AC TENT INTERFACE PANEL circuit breaker to ON, TM11-7010-256-12&P.5. Measure voltage between terminal 1 (4) of circuit breaker CB10(5) to anywhere on bus bar E4 (6). Repeat measurement forterminal 2 (7) to bus bar E4.6. Does multimeter read 110 volts AC for each measurement?YESNOBYN1. Replace circuit breaker CB10(WP 0828 00).2. Verify no faults found.0091 00-4