TM 9-2350-277-20-1
NO AC POWER FROM TENT INTERFACE PANEL A5 (M1068A3 ONLY)Continued
0091 00
BY
1. Remove ALL power from SICPS system, (see your -10) and TM
11-7010-256-12&P.
2. Remove ten screws (1) and lockwashers (2), and lower faceplate
(3). Discard lockwashers.
3. Apply AC power to the SICPS system, (see your -10) and TM
11-7010-256-12&P.
4. Set AC TENT INTERFACE PANEL circuit breaker to ON, TM
11-7010-256-12&P.
5. Measure voltage between terminal 1 (4) of circuit breaker CB10
(5) to anywhere on bus bar E4 (6). Repeat measurement for
terminal 2 (7) to bus bar E4.
6. Does multimeter read 110 volts AC for each measurement?
YES
NO
BYN
1. Replace circuit breaker CB10
(WP 0828 00).
2. Verify no faults found.
0091 00-4