TM 9-2350-277-20-1
NO POWER FROM ROADSIDE AC POWER EXTENSION BOX A6 (M1068A3
ONLY)
0093 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Digital Multimeter (WP 0926 00, Item 30)
Materials/Parts
Lockwasher (10)
Personnel Required
Power-Generation Equipment Repairer 52D10
Helper (H)
References
See your -10
TM 11-7010-256-12&P
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
WARNING
HIGH VOLTAGE is used in the operation of this equipment.
DEATH ON CONTACT may result if personnel fail to observe safety precautions.
NEVER work on equipment unless at least one other person familiar with the operation and
hazards of the equipment is nearby. That person should also be familiar with giving first aid.
When an operator helps a mechanic, that operator must be warned about dangerous areas.
SHUT OFF POWER supply to equipment before beginning work. Make sure all external power
is off/disconnected.
BE CAREFUL not to contact high-voltage connections when installing or operating this
equipment.
0093 00-1