TM 9-2350-277-20-1
POWER CONTROL ENCLOSURE A1 DC INPUT/OUTPUT INOPERATIVE (M1068A3
ONLY)Continued
0090 00
C4Y
1. Remove cable W38 plug P7 (1) from Power Control Enclosure
jack J28 (2).
2. Measure resistance between center of plugs P7 (1) and P6 (3) of
cable W38.
3. Does multimeter read 0 ohms?
YES
NO
C4YN
1. Replace cable W38 (WP 0850 00).
2. Verify no faults found.
0090 00-14