HYDRAULIC ACTUATOR REPAIR (CONTINUED)
Lightly lubricate end cap seals and gland seals with
hydraulic fluid. Install end cap (14) and gland (18) on
cylinder (11).
Install four tie rods (21) through gland (18) and end cap (14).
Install four nuts (22) on cap-end of four tie rods (21).
Install four nuts (23) on gland end of tie rods. Torque four
gland-end nuts evenly in a cross pattern style (see illlustra-
tion for sequence) as follows:
1. Tighten all four bolts to 5 lb-ft on first cycle.
2. Tighten all bolts to 20 lb-ft on second cycle.
3. Tighten all bolts to 40 lb-ft on third cycle.
4. Finally, tighten all bolts to 60-64 lb-ft on fourth cycle.
NOTE
If actuator is to be shipped or stored, coat non-
painted areas with corrosion preventive (item 60,
Appx B).
Q Install caps (24) in each fluid port.
11-21/(11-22 blank)
TM 9-2350-267-34