HYDRAULIC ACTUATOR REPAIR (CONTINUED)MNOPQLightly lubricate end cap seals and gland seals with hydraulic fluid.Install end cap (3) and gland (4) on cylinder (5).Install four tie rods (2) through gland (4) and end cap (3).Install four nuts (1) on cap-end of four tie rods (2).Install four nuts (23) on gland end of tie rods. Torque four gland-endnuts evenly in a cross pattern style (see illustration for sequence)as follows:l. Torque all four bolts to 5 lb-ft on first cycle.2. Torque all bolts to 20 lb-ft on second cycle.3. Torque all bolts to 40 lb-ft on third cycle.4. Finally, torque all bolts to 60-64 lb-ft on fourth cycle.NOTEIf actuator is to be shipped or stored, coat non-paintedareas with corrosion preventive (item 60, Appx B).Install caps (24) in each fluid port.11-21/(11-22 blank)Change 4TM 9-2350-267-34