(p 6-89)(p 6-84)2-124Change 1TM 9-2350-267-20NOTEFor steps G, H, I and J, use jumper wires withalligator clips.G Disconnect the generator (alternator)-to-rectifier harness atthe rectifier. With jumper wires, connect pin E of the harnessconnector to a battery negative terminal and pin D of the con-nector to the positive terminal of the same battery to apply 12volts dc to the alternator field. With the engine running at idlespeed and the multimeter set on the ac volts scale, place redlead on pin A and black lead on pin B and note voltage reading.Place red lead on pin B and black lead on pin C and notereading. Then place red lead on pin C and black lead on pin Aand note reading. All readings should be between 30 and 34voltages. If these voltages are present, reconnect harness andgo to step I. If these voltages are not present or vary con-siderably, go to step H.TA312701