D Disconnect wire 10 to cage and panel lights circuit breaker.Place red multimeter lead in wire 10 and black lead to ground.Check for voltage. If voltage is not present, replace wire 10(p 6-77). If voltage is present, reconnect and go to step E.EDisconnect wire 27 at circuit breaker. Place red lead ofmultimeter in circuit breaker output. Check for voltage. Ifvoltage is not present, replace circuit breaker (p 6-54). If voltageis present, go to step F.TA3127002-123Change 1TM 9-2350-267-20