STACKER HYDRAULIC BRAKE: REMOVAL AND INSTALLATION
(CONTINUED)
REMOVAL
WARNINGS
Make sure all systems are shut down and
MASTER switch is OFF. Hydraulic fluid maybe
HOT.
Do not perform removal of procedures until
backup hydraulic gage has been checked visually.
Gage must show 0 psi.
CAUTION
Cap hydraulic lines and ports immediately after
disconnecting to prevent contaminants from enter-
ing hydraulic system and hydraulic components.
A Disconnect hydraulic hose (1) from elbow (2).
B
Remove two screws (3) and two lockwashers (4). Discard
lockwashers.
C Pull brake (5) from motor (6).
D Remove elbow (2), packing (7) and expander (8) from brake (5).
Discard packing.
INSTALLATION
A
B
C
D
Install expander (8), new packing (7) and elbow (2) on brake (5).
Position brake (5) on motor (6) and turn brake (5) until screw
mounting holes aline.
Secure brake (5) on motor (6) with two screws (3) and two new
lockwashers (4).
Connect hydraulic hose (1) to elbow (2).
TA313049
12-42.1
Change 1
TM 9-2350-267-20