TM9-2350-261-34
16.
17.
18.
Remove eight locknuts (l), washers (2), and
19.
screws (3). Separate master switch panel
assembly (4) from distribution box (5).
Discard locknuts.
Remove screw (6), lockwasher (7), and
circuit 6 lead (8) from bus bar (9). Remove
20.
circuit 6 lead and grommet (10) from
distribution box (5). Discard grommet and
lockwasher.
On 100 amp generator system, remove
screw (11), lockwasher (12), and circuit 3
lead (13) from circuit breaker (14). Remove
circuit 3 lead and grommet (15) from
distribution box (5). Discard grommet.
On 100 amp generator system, remove
screw (16), lockwasher (17), and circuit 2
lead (18) from bus bar (9). Remove circuit 2
lead and grommet (19) from distribution box
(5). Discard grommet and lockwasher.
On 200 amp generator system, remove
screw ( 16), lockwasher ( 17), circuit 2B lead
(20), and circuit 2 lead (18) from bus bar
(9). Remove circuit 2B lead, circuit 2 lead,
and two grommets (19 and 21) from
distribution box (5). Discard grommets and
lockwasher.
FOR 100 AMP GENERATOR SYSTEM
FOR 200 AMP GENERATOR SYSTEM
L
GO TO NEXT PAGE
6-35