TM 9-2350-261-20-4
REPLACE AC LIGHT CABLE (W11) (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Personnel Required
Maintenance Level
Power-Generation Equipment Repairer 52D10
Unit
Equipment Condition
Tools and Special Tools
Engine stopped (see your -10)
Carrier blocked (see your -10)
Materials/Parts
All external power disconnected (TM 11-7010-256-
Tie strap (5)
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Disconnect cable W11 plug P17 (1) from power control box A1 jack J37 (2).
2.
Remove three screws (8) and loop clamps (3).
3.
Remove five screws (9) and loop clamps (4).
4.
Remove and discard five tie straps (5).
5.
Remove two screws (10) and loop clamps (6).
6.
Disconnect cable W11 plug P2 (11) from AC light plug P1 (7).
7.
Remove cable W11 (12) from carrier.