REPLACE INVERTER DC CABLE (W6) (M1068 ONLY) -- Continued
0742 00
INSTALLATION
1.
Install harness W6 in carrier. Route leads behind inverter housing A2 (1) to front face plate (2).
2.
Connect harness W6 terminal E1 (3) to ground post G3 (4). Use screw (5) and new lockwasher (6). Make sure there
are two leads connected to ground post G3.
3.
Connect harness W6 terminal E2 (7) to terminal block TB1 (8) on inverter housing faceplate (2).
4.
Attach faceplate (2) to front of inverter housing A2 (1) using ten screws (9) and new lockwashers (10).
5.
Connect cable W6 plug (11) to power control box A1 jack J26 (12).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Turn MASTER SWITCH to ON (see your -10). Check that electrical system works properly. See TM
11-7010-256-12&P.
3.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK