TM 9-2350-261-20-4
0709 00
ACCESS PLATE AIR HOSE (M1059 ONLY) -- Continued
INSTALLATION
Secure air hose (1) to carrier hull with three clamps (6), new lockwashers (5), and screws (4).
1.
2.
Connect air hose (1) to adapter plate fitting (3).
3.
Connect air hose (1) to compressor reservoir fitting (2).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Set circuit breaker CB1 to ON. See TM 3-1040-283-10.
END OF TASK