TM 9-2350-261-20-4
REPLACE SMOKE GENERATOR ADAPTER ACCESS PLATE AND GASKET
0708 00
(M1059 ONLY) -- Continued
INSTALLATION
WARNING
Before you do any maintenance, discharge all capacitors to ground or electrical shock could
injure personnel.
1.
Install two elbows (1) on adapter access plate (2). Secure with two jamnuts (3) and new lockwashers (4).
2.
Install gasket (5) on plate (2).
3.
Install dust cover (6) and fitting (7) on plate (2). Secure with four screws (8) and new locknuts (9).
4.
Install interior cable (18), four screws (16), and new locknuts (17) on adapter access plate (2).
5.
Connect exterior cable (15) to interior cable (18) on adapter access plate (2).
6.
Install plate (2) on hull. Secure with four screws (10) and new lockwashers (11).
7.
Connect electrical cable assembly (12) to plate fitting (7).
8.
Connect air hose (13) and fog oil hose (14) to two elbows (1).