TM 9-2350-261-20-2R E P L A C E I N F R A R E D P O W E R S U P P L Y S H O C K M O U NTB R A C K E T SINITIAL SETUP Tools:Personnel Required:General Mechanics Tool Kit (Item 30, App D)Unit MechanicMaterials/Parts:Equipment Conditions:Lockwasher (8)Infrared power supply removed (page 12-134)1.2.Remove four screws (1), eight lockwashers(2), four flat washers (3), ground strap (4),and two brackets (5) from hull. Discardlockwashers.Remove eight nuts (6), washers (7), screws(8), and four mounts (9) from twobrackets (5).CLEAN, INSPECT, AND REPAIR 3. Check ground lead. Replace frayed, broken, orcracked parts (page 14-3).INSTALL 4.5.Install four mounts (9) in two brackets (5).Secure with eight screws (8), washers (7),and nuts (6).Install two brackets (5) on hull. Secure witheight new lockwashers (2), four flat washers(3), ground strap (4), and four screws (1).FOLLOW-THROUGH STEPS 1. Install infrared power supply (page 12-134).END OF TASKREMOVE 12-136
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business