TM 9-2350-261-20-2DISCONNECT/CONNECT BATTERY GROUND LEADINITIAL SETUP Tools:General Mechanics Tool Kit (Item 30, App D)Battery Terminal Puller (Item 46, App D)Materials/Parts:Grease (Item 18, App C)Personnel Required:Unit MechanicReferences:See your -10Equipment Conditions:Engine stopped/shutdown (see your -10)Ramp lowered (see your -10)and radios and heaters OFF (see your -10)Battery access (see your -10 page 3-35)Battery access cover removed M1068 ONLY(page 13-6.1)DISCONNECT1.W A R N I N GGas from batteries can ex-plode. Ventilate compart-ment before you disconnector connect battery cables.Battery acid can burn orblind you. Do not get acidon your skin or eyes. ALWAYS disconnectground lead (circuit 7) first and connect itlast.WARNINGBattery posts and cablestouched by metal objectscan short circuit and bumyou. Do not wear jewelry,necklaces, or watches whenworking on the electricalsystem. Keep tools - away from posts,wires, and terminals.Loosen nut (1) and remove circuit 7 groundlead and terminal lug (2) from battery post(3). Use battery terminal puller.CONNECT2.3.C A U T I O NBattery cells can be damaged if the bat-teries are connected incorrectly. Be surebatteries are connected correctly.Position circuit 7 ground lead and terminallug (2) on battery post (3) and tightennut (l).Coat top of battery post (3) and terminal lug(2) with grease.—FOLLOW-THROUGH STEPS 1. Secure battery (see your -10 page 3-35).3. Raise and lock ramp (see your -10).2. Start engine (see your -10).4. Stop/shutdown engine (see your -10).END OF TASK