TM 9-2350-261-20-2
R E P L A C E D O M E L I G H T C I R C U I T B R E A K E R
( M 5 7 7 A 2 A N D M 1 0 6 8 O N L Y)
I N I T I A L S E T U P
Tools:
References:
General Mechanics Tool Kit (Item 30, App D)
See your -10
Materials/Parts:
Equipment Conditions:
Gasket
Engine stopped/shutdown (see your -10)
Self-locking nut (8)
Battery ground lead disconnected (page 13-2)
Personnel Required:
Unit Mechanic
1.
2.
3.
4.
Remove eight locknuts (l), washers (2),
screws (3), and master switch panel (4) from
distribution box (5). Discard locknuts.
Disconnect two circuit 10 leads (6) from cir-
cuit breaker (7).
Remove two nuts (8), screws (9), and circuit
breaker (7) from master switch panel (4).
Inspect gasket (10). Replace if damaged.
5.
6.
7.
Place circuit breaker (7) in master switch
panel (4). Secure with two screws (9) and
nuts (8).
Connect two circuit 10 leads (6) to circuit
breaker (7).
Place master switch panel (4) on distribution
box (5). Secure with eight screws (3),
washers (2), and new locknuts (1).
F O L L O W - T H R O U G H S T E PS
1. Connect battery ground lead (page 13-2).
2. Turn MASTER SWITCH ON. Operate dome
lights to check that circuit breaker is
operable. Turn all switches OFF
(me your -10).
END OF TASK
12-70
Change 3
I N S T A L L
R E M O V E