TM 9-2350-261-20-1REPLACE AIR CLEANER HOUSINGDESCRIPTIONThis task covers: Remove (page 7-7).Install (page 7-8).INITIAL SETUPTools:Equipment Conditions:General Mechanics Tool Kit (Item 30, App D)Personnel Required:Unit MechanicReferences:See your -10REMOVEEngine stopped/shutdown (see your -10)Carrier blocked (see your -10)Trim vane lowered (see your -10)Power plant front access door open(see your -10)Driver’s power plant access panel removed(page 24-25)1.2.NOTEYou will have one of two air cleanerconfigurations. Body and elements arenot interchangeable except as sets.Release four latches (1), remove housing (2)and element (3) from cover (4).Remove element (3) from housing (2).GO TO NEXT PAGEChange 4 7-7