TM 9-2350-261-20-1
REPLACE AIR CLEANER HOUSING
DESCRIPTION
This task covers: Remove (page 7-7).
Install (page 7-8).
INITIAL SETUP
Tools:
Equipment Conditions:
General Mechanics Tool Kit (Item 30, App D)
Personnel Required:
Unit Mechanic
References:
See your -10
REMOVE
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Trim vane lowered (see your -10)
Power plant front access door open
(see your -10)
Drivers power plant access panel removed
(page 24-25)
1.
2.
NOTE
You will have one of two air cleaner
configurations. Body and elements are
not interchangeable except as sets.
Release four latches (1), remove housing (2)
and element (3) from cover (4).
Remove element (3) from housing (2).
GO TO NEXT PAGE
Change 4 7-7