3-208TM 9-2350-261-20-11. Does heater continue producing hot air for 10 min-1. Heater shuts off prema-utes?turely.\2. Notify your supervisor.1. Listen to heater blower.2. Turn HI/LO switch to HI.3. Does blower sqeed increase?3-216Y ES1. Feel heater hot air outlet.1. Shut off heater2. Has air temperature increased?(see your -10).I2. Faulty heater restrictorIYESsolenoid.3. Notify your supervisor.1. Run heater on HI for 10 minutes.NOTEHeater will shut off prematurely if airinlet temperature is 60 degrees or above.This is normal.2. Does heater continue producing hot air?1. Shut off heater(see your -10).2. Insuflicient heateroperation.3. Notify your supervisor.1. Turn HEATER SWITCH to OFF.1. Heater does not purge.2. Does blower remain on?2. Notify your supervisor.1. Listen to heater until blower shuts off.2. Does blower shut off in less than 5 minutes?1. Heater is operating properly.2. No faults found.1. Faulty heater flamedetector switch.2. Notify your supervisor.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business