P E R S O N N E L H E A T E R M A L F U N C T I O N S CONT.
P E R S O N N E L H E A T E R M A L F U N C T I O N S CONT. - TM-9-2350-261-20-1_420
TM-9-2350-261-20-1 Carrier Personnel Full Tracked Armored M113A2 2350-01-068-4077 Carrier Command Post Light Tracked M577A2 2350-01-068-4089 Manual
Page Navigation
384
385
386
387
388
389
390
391
392
393
394
TM 9-2350-261-20-1
1. Remove heater control box (page 29-42).
2. Measure
resistance
between circuit breaker
terminals 16 (1) and 17 (2).
3. Does
multimeter
read 0 ohms?
Y ES
1. Measure
resistance
between lead ends from circuit
breaker terminal 17 (1) to indicator light terminal
3 (2).
2.
Does
multimeter
read
0
ohms?
1. Replace heater circuit
breaker (page 29-44).
2. Verify no faults found.
1. Repair/replace faulty lead
(page 14-3).
2. Verify no faults found.
1. Replace indicator light assembly (page 29-44).
2. Verify no faults found.
3 - 2 1 0