TM 9-2350-261-20-11. Measure voltage between bulb socket center contact(1) and ground (2).2. Does multimeter read less than 17 volts?YES1. Turn MASTER SWITCH to OFF.2. Remove master switch panel from distribution box(page 9-13). Do not disconnect battery negativelead.3. Remove plug 450 B (1) and plug 450 C (2) fromfront bilge pump circuit breaker (3) or remove plug450 (4) and plug 450 A (5) from pump bilge PumPcircuit breaker (6).4. Measure resistance between circuit breaker jacks.5. Does multimeter read 0 ohms?I1. Replace BILGE PUMPSON indicator light-assembly (page 11-5).2. Verify no faults found.1. Replace bilge pump circuitbreaker (page 16-12).2. Verify no faults found.GO TO NEXT PAGE3-203