P E R S O N N E L H E A T E R M A L F U N C T I O N S CONT. - TM-9-2350-261-20-1_420
P E R S O N N E L H E A T E R M A L F U N C T I O N S CONT. - TM-9-2350-261-20-1_422
TM-9-2350-261-20-1 Carrier Personnel Full Tracked Armored M113A2 2350-01-068-4077 Carrier Command Post Light Tracked M577A2 2350-01-068-4089 Manual
Page Navigation
386
387
388
389
390
391
392
393
394
395
396
TM 9-2350-261-20-1
1.
2.
3.
Remove heater control box (page 29-42).
Measure
resistance
between lead ends from circuit
breaker terminal 17 (1) and ON/OFF/STA.RT
switch terminal 15 (2).
Does
multimeter
read 0 ohms?
1. Measure
resistance
between lead ends from
ON/OFF/START switch terminals 21 (1) and
14 (2).
2. Does
multimeter
read 0 ohms?
1. Replace heater ON/OFF/START switch
(page 29-43).
2. Verify no faults found.
1. Repair faulty lead
(page 14-3).
2. Verify no faults found.
1. Repair heater switch jump-
er lead between terminal
21 and 14 (page 14-3).
2. Verify no faults found.
3-212
.