TM 9-2350-261-20-1SUSPENSION LOCKOUT DOES NOT HOLD (M741A1 ONLY) INITIAL SETUP ToolsGeneral MechanicsMaterials/PartsWood blockReferences:Tool Kit (Item 30, App D)See your -10See your -12Equipment Conditions:Engine stopped/shutdown (see your -10)Personnel Required:Carrier blocked (see your -10)Unit MechanicRamp lowered (see your -10)Helper (H)1. Raise and lower ramp (see your -10)2. Does ramp raise normally?YES1. Check hydraulic reservoir fluid level (see your -12).2. Is reservoir level correct?1. Extend suspension lockout cylinders (see your -10).2. Do all suspension lockout cylinder push rods fully.1. Troubleshoot ramp system:See task: Ramp operationis slow or sluggish(page 3-184), or Ramp willnot raise or free falls(page 3-185).2. Verify no faults found.1. Replace suspension lockoutcylinder(s) which does notextend (page 28-72).2. Verify no faults found.3 - 1 9 2
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business