TM 9-2350-261-20-1
1.
2.
3.
4.
5.
NOTE
Hydraulic fluid may drain from discon-
nected tubes and valves. Use wiping
rags.
Remove tube fitting (1) from control valve return
port (2).
Observe return port (2).
NOTE
If hydraulic fluid flows from return port
during step 3 or 4, stop engine and go to
step 5.
Start engine and let idle (see your -10).
Move control valve to EXTEND position.
Does fluid fail to flow from selector valve return
port?
1. Replace ramp control valve
(page 28-84).
2. Verify no faults found.
I