TM 9-2350-261-20-1S U S P E N S I O N L O C K O U T I N D I C A T O R M A L F U N C T I O NS( M 7 4 1 A 1 O N L Y)INITIAL SETUPTools:General MechanicsDigital MultimeterJumper WirePersonnel Required:Unit MechanicReferences:See your -10Tool Kit (Item 30, App D)(Item 43, App D)Equipment Conditions:Engine stopped/shutdown (see your -10)Carrier blocked (see your -10)Trim vane lowered (see your -10)Power plant front access door open(see your -10)Driver’s power plant access panel removed(see your -10)Power plant rear(see your -10)access panels removed1.2.3.Remove SUSPENSION LOCKOUT indicator coverlens (l), gasket (2), bulb (3) and gasket (4).Measure resistance between bulb center contact (5)and bulb base (6).Does multimeter read 0-5 ohms?1. Replace SUSPENSIONLOCKOUT indicator bulbI(page 11-22).2. Verify no faults found.3-164