E N G I N E C R A N K S S L O W L Y CONT. - TM-9-2350-261-20-1_221
E N G I N E C R A N K S B U T W I L L N O T S T A R T
TM-9-2350-261-20-1 Carrier Personnel Full Tracked Armored M113A2 2350-01-068-4077 Carrier Command Post Light Tracked M577A2 2350-01-068-4089 Manual
Page Navigation
188
189
190
191
192
193
194
195
196
197
198
TM 9-2350-261-20-1
1. Remove eight nuts (1), washers (2), and screws (3)
from master switch panel (4). Pull panel away
from distribution box (5).
2. Inspect terminal end(s) on master switch (6).
3. Are terminal end and master switch free from
corrosion and/or other damage?
1. Verify no faults found.
1. Repair battery to master
power cable and/or master
switch (page 14-9).
2. Verify no faults found.