TM 9-2350-261-20-1
1. Has neutral start switch been adjusted?
1. Replace neutral start switch (page 23-53).
2. Verify no faults found.
1.
2.
3.
4.
5.
6.
Remove instrument panel for access (page 11-2).
Remove front main wiring harness circuit 14 plug
(1) from panel power harness circuit 14 jack (2).
Turn MASTER SWITCH to ON.
Measure voltage between circuit 14 jack (2) and
ground.
Does multimeter read less than 17 volts?
Turn MASTER SWITCH to OFF.
1. Repair panel power wiring harness (page 14-3).
2. Verify no faults found.
3-24
1. Adjust neutral start switch
(page 23-53).
2. Verify no faults found.
1. Repair front main wiring
harness circuit 14
(page 14-3).
2. Verify no faults found.