TM 9-2350-261-20-1
E N G I N E C R A N K S B U T W I L L N O T S T A R T B E L O W 4 0 ° ( A I R B OX
H E A T E R I S U S E D )
INITIAL SETUP
Tools:
General Mechanics Tool Kit (Item 30, App D)
Digital Multimeter (Item 43, App D)
STE/ICE-R Test Set (Item 71.1, App D)
Personnel Required:
Unit Mechanic
Helper (H)
References:
See your -10
References (cont):
STE/ICE-R engine will crank
but will not
start troubleshooting
Equipment Conditions:
(page 3-271)
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Trim vane lowered (see your -10)
Power plant access door open (see your -10)
Drivers power plant access panel removed
(see your -10)
Power plant rear access panels removed
(see your -10)
1. Remove air pump to air box heater hose (1) from air
box (2).
2. Turn MASTER SWITCH to ON (see your -10).
3. Turn air box heater switch to ON.
4. Does airflow from end of hose?
3-34 Change 1
GO TO PAGE 3-38