TM 9-2350-261-10
The assembly has connections for A.C. power out and external power in. By
connecting either cable W 1 or W2 to the assembly connections, the carrier can act as
an alternate power source or receive power from some other alternate power source.
Cable W1 and W2 are located just behind the generator on top of the carrier. Cable 2
has connectors on both ends which allow it to be connected between other systems.
Cable W1 has a connector on one end and pigtails (loose wires) on the other end.
This allows connection to power sources other than a common system. Cables W 1
and W 2 can also be connected in series when additional length is required.
Connections for cable W1 pigtails are:
Items in parenthesis identify labels on
Circuit 1 to HOT (Power)
Circuit 2 to Neutral (Neutral)
Circuit 3 to Ground 1 (GND 1)
Circuit 3 to Ground 2 (GND 2)
each wire.
When operating on earner power, only essential systems should be operated to avoid
overloading the power requirements.
1-36.2
Change 3