TM 9-2350-247-20-3REPLACE NBC FILTERED AIR HOSE (M548A3) — Continued 0537 00INSPECTION1. Inspect quick disconnect coupling for wear, grooves, nicks, scratches, and loose fittings that may cause quick disconnectcoupling to leak. Replace quick disconnect coupling if leakage is suspected.2. Inspect filtered air hose for cracks, wear, crimps, and breaks that could cause air leaks. Replace hose that shows signs ofleakage.3. Inspect ratchet clamps for deformation and excessive wear. Replace clamps that show either of these defects.INSTALLATION1. Install ratchet clamp (1) on each end of filtered air hose (2).2. Install filtered air hose (2) on outlet adapter (3) on M3 heater (4) and quick disconnect coupling (5).3. Install quick disconnect coupling (5) on orifice connector assembly (6).END OF TASK0537 00-3/4 blank
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business